NEWS

News

The latest news, milestones and highlights from eXDCi Solutions.

09.09.2026

Gateway for managing multiple SDO requests over a CANopen network

At eXDCi Solutions we developed our own queue management strategy to optimise data exchange between Modbus TCP and CANopen. To validate performance, we set up a lab environment with an M251 controller and two Schneider Electric ATV61 drives, also monitoring CANopen communications with a PEAK-System PCAN-USB. The result: 4 read requests and 4 write SDO requests in 30 ms, consistently. This kind of testing lets us validate not only functionality but also how our solution behaves under real communications load. Development and validation of industrial communication solutions at eXDCi Solutions.

View on LinkedIn →

03.09.2026

91 Modbus TCP devices communicating simultaneously with a Schneider Electric M262 PLC

At eXDCi Solutions we developed an explicit Modbus TCP messaging project to increase the communication performance and capacity of an M262 (TM262L20MESE8T). In our tests: 91 simultaneous Modbus TCP devices, 120 registers per request, an average time of <±10 ms per request/device, 984 hours of continuous operation, and the ability to make online changes without stopping the PLC. A good example of how programming and communications architecture can make the difference in an industrial application.

View on LinkedIn →

21.08.2026

PME + vNode: how do you integrate an energy management system and a real-time data acquisition system without interference?

The Schneider Electric Power Monitoring Expert (PME) system manages the facility's energy data, enabling real-time visualisation and the generation of reports with historical data. The new challenge was to add vNode as a real-time data acquisition system, while keeping the existing PME system running at the same time. The difficulty lay in the communications architecture. Many devices communicate via Modbus TCP/Modbus RTU gateways, with several devices sharing the same RS485 networks. In this scenario, two systems making requests directly to the same equipment could affect communications performance. We added a Schneider Electric M580 controller as an intermediate element for data acquisition and communications management.

View on LinkedIn →

18.08.2026

Launching Kit eXDCi BackupLink: a temporary continuity solution for industrial communications

When the main link fails, 2 ETIC Telecom IPL-C-100-LW routers are deployed, one at each end, establishing a VPN tunnel over the 4G/LTE mobile network, keeping industrial communications running transparently.

View on LinkedIn →

10.07.2026

Gateway Proxy development for Microcom equipment

Development of a proxy that connects Microcom telecontrol devices with the NETxAutomation BMS, leveraging the information published on ZeusCloud.

View on LinkedIn →

01.07.2026

Launching our Connected Machine solution

Sending relevant data to eXDCi's connected system for automated report delivery, improving traceability, improving support and providing useful information.

View on LinkedIn →

04.03.2026

Professional connectivity with EticSIM PRO guarantees

Multi-operator solution across Europe. A B2B solution with guaranteed QoS, where speed depends only on signal quality, even in environments with high user concurrency.

View on LinkedIn →

12.02.2026

ETIC Telecom equipment now complies with the IEC62443-4-2 standard

We are pleased to announce that ETIC Telecom's RAS/IPL products officially comply with the IEC62443-4-2 standard.

View on LinkedIn →

09.02.2026

High-availability solution for fibre optic networks

A solution that, using ETIC Telecom's XSLAN and IPL equipment, allows an RSTP ring to be closed via 4G routers.

View on LinkedIn →

03.02.2026

Secure and simple point-to-point 4G communication

ETIC Telecom routers make VPN configuration easy and allow you to work at layer 2 without complications.

View on LinkedIn →

28.01.2026

Global Client solution with AVEVA PlantSCADA

We tested how AVEVA PlantSCADA GlobalClient is the perfect solution for unifying several PlantSCADA applications at a central site.

View on LinkedIn →

16.01.2026

ETIC's XELAN, the ideal solution for converting RS485 to Ethernet

Using Modbus RTU or Profibus DP? Move up to Ethernet without changing your cabling.

View on LinkedIn →

15.01.2026

First PME implementation of 2026

A new project that reinforces our commitment to energy efficiency, digitalisation and smart energy management.

View on LinkedIn →

07.01.2026

Level 2 certification renewed with ETIC Telecom

In 2026 we continue our commitment to a professional level of support for ETIC Telecom solutions.

View on LinkedIn →

2016

eXDCi Solutions named "ETAP Service Provider"

ETAP recognises us as a Select-level Service Provider, giving our clients greater assurance on electrical studies performed with ETAP Power Station.

2016

Success story: over 1000x more bandwidth on a telecontrol network

We replaced ageing V23 modems with ETIC Telecom SHDSL switches, multiplying the communications capacity over the same existing cable.